InquiryABB 3HAC035301-001 is the DSQC 406 Drive Unit, the Main Drive Unit for small robots listed as MDU-430A in the ABB IRC5 spare parts table. ABB lists it for the IRC5 Single controller and for IRB 140, IRB 1410, IRB 1600, IRB 260, IRB 360 and IRB 120 with a Single Controller. ABB assigns a different main drive unit to large robots and a separate rectifier unit when additional drive units are fitted, so the drive unit label, the controller nameplate and the cabinet layout are what decide the match. Send us the complete number from the drive unit label, the controller nameplate, the robot model and serial and a photo of the drive module layout, and we confirm the drive unit before you order.
| Manufacturer | ABB (original spare part) |
| Part Number | 3HAC035301-001 |
| Official Product Name | DSQC 406 Drive Unit |
| Drive Unit Type | Main Drive Unit, MDU-430A (small robots), as listed in the ABB IRC5 product manual |
| ABB Type Designation | 41x37,5x25 |
| Controller Platform | IRC5 Single, as listed in the Categories field of the ABB data sheet |
| Robot Fit | IRB 140, IRB 1410, IRB 1600, IRB 260, IRB 360 and IRB 120 with Single Controller, as stated in the Technical field of the ABB data sheet |
| Robotics Part Category | Drive Module |
| Different Parts | The main drive unit for large robots, the additional drive units, the rectifier unit for small robots with an additional drive unit, and other revisions of this number are each separate ABB articles |
| Fit Confirmation | Send the complete number from the drive unit label, the controller nameplate, the robot model and serial and a photo of the drive module layout; we confirm the drive unit before you order |
| Condition | New original or used original. Please confirm the condition with us before ordering. |
Send the complete article number from the drive unit label rather than a partial number: ABB uses separate numbers for each drive system configuration.
This main drive unit is fitted in the drive module of the IRC5 Single controller, where it supplies the servo power for the axes of the smaller ABB robots. ABB's data sheet names the IRB 140, IRB 1410, IRB 1600, IRB 260, IRB 360 and the IRB 120 with a Single Controller, and the IRC5 spare parts table identifies the unit as the MDU-430A for small robots. It is the part a service team reaches for when a drive fault stops the robot, when an axis will not enable, or when the unit has been damaged by overheating or a power event. The same controller family uses different drive hardware for larger robots and for cells with additional axes, so the robot model, the controller nameplate and the physical layout of the drive module must be recorded on the job rather than inferred from the unit's appearance. We match all three against your labels before quoting.
The IRC5 drive module converts the controller's motion commands into the power that drives the robot motors, and the main drive unit is the assembly that carries out that conversion for the robot axes. ABB splits this hardware by robot size and by drive system configuration: the IRC5 product manual lists the MDU-430A for small robots, the MDU-790A for large robots, and a separate ARU-430A rectifier unit for small robots fitted with an additional drive unit. The data sheet for this article also names the IRC5 Single controller and a specific set of small-robot models. That split is why a drive unit that looks similar on a bench can be the wrong part: the unit type, the controller variant, the robot model and the positions occupied in the drive module together define the correct article. ABB's manuals also require the drive system configuration to be checked when drive hardware is exchanged, because the axis assignments and any external-axis hardware have to follow the cabinet that is actually installed. We confirm the article, the controller and the cabinet layout with you before quoting.
Main drive units fail in a few repeatable ways: a drive fault that prevents the motors from enabling, an over-temperature or over-current event, a failed cooling path through the cabinet, degraded power components after long service, and backplane or signal connector damage that shows up as a communication fault. Because a drive fault can also originate in the motor cable, the feedback chain or the incoming supply, those parts should be checked before the drive unit is condemned. When the unit is exchanged, isolate and lock out all controller supplies, follow the ABB cabinet service procedure for stored energy, use ESD precautions and photograph the original unit label, slot position, cable routing and every connector before removal. Identify each motor connector as it is disconnected, retain all protective-earth connections and fit the replacement in the same position with the original cable routes. On power-up, check the drive system configuration and the axis assignments, verify the safety and enabling circuits, then jog each axis at low speed and run one complete production cycle before returning the cell to automatic.
The ABB 3HAC029818-001 DSQC 663 main drive unit is a different part for large robots; the ABB 3HAC030923-001 DSQC 664 additional drive unit and the ABB 3HAC025338-001 main servo drive unit are different parts from this one. Browse our ABB Drive Units & Servo Motors range for other drive assemblies, or send us your drive unit label and we confirm the matching part.