InquiryThe KUKA 00-134-932 is the CI3 Technology board of the ESC safety logic in the KR C2 edition 2005 controller. The safety logic of that controller is the part that decides whether the robot is allowed to move: it watches the emergency stop, the safety gate, the enabling switch and the axis limits, and it holds the drives off when the chain is not closed. The CI3 board is where that safety circuit is realised in hardware, and the unit comes with its adapter plate so it fits the cabinet slot directly. This version is the CI3 board that carries its own node and works with the MFC3 Tech card, which is what the safety circuit needs when it drives a shared pendant, a SafetyBus gateway or external axes. Send us the article number on the board in your cabinet or the controller serial number, and we confirm the match before you order.
| Manufacturer | KUKA (original spare part) |
| Part Number | 00-134-932 |
| Product name | CI3 Technology safety board |
| Type | CI3 board of the ESC electronic safety circuit |
| Controller series | KUKA KR C2 edition 2005 |
| Scope | Monitoring of the emergency stop, the safety gate and the axis limits in the safety circuit |
| Version | The CI3 board with its own node, used together with the MFC3 Tech card |
| Accessory | Adapter plate included |
| Alternative article number | 00-138-968 |
| Condition | New original or used original. Please confirm the condition with us before ordering. |
| Details confirmed before supply | The board version and the version of the safety configuration are confirmed against the board in your cabinet before we ship. Send us the article number on the board or the controller serial number. |
Send the article number printed on the board, the controller serial number or a photo of the board, and we confirm the match before you order.
The safety circuit of a robot controller is a separate system from the motion control, and it is deliberately built so that the two do not depend on each other. The ESC is the electronic safety circuit that closes the chain of protective signals, and the CI3 board is the hardware that carries that chain inside the cabinet. Every safety signal runs on two independent channels, and the CI3 board evaluates them, which is why a fault on one side shows up as a dual channel discrepancy rather than a clean open. The CI3 family exists in several versions because the cabinet architecture changed over the years: the CI3 Standard board is the one used as standard and has no node of its own, it only connects the nodes that are present and distributes the signals to the interfaces, while the CI3 Tech board carries its own node and is needed for the shared pendant, the SafetyBus gateway, the output to a top mounted cabinet for external axes and the power supply of a second RDC. The CI3 Technology board is the version built for the CI3 Tech configuration, and it has to be used together with the MFC3 Tech card, which is the card that carries the system I/Os and the SafeRobot interface. That pairing is why the board in your cabinet has to be identified by its article number rather than by the label on the front, and it is also why the board and the MFC card are checked as a pair before a replacement is shipped.
The KUKA KR C2 edition 2005 operating instructions describe the ESC diagnosis, where the controller shows the state of every node in the safety circuit and the accumulated errors, and where the recorded data is written to a log file. They also set out the customer interface rules that the CI3 board works to: the emergency stop, the enabling switch and the safety gate each run as a dual channel input, and an input that is not used has to be jumpered, because an open chain is what keeps the drives off. Please contact us with the fault code shown on your controller for an accurate diagnosis of your cabinet. One point is worth keeping in mind when the safety board is replaced: a fault that appears on several safety signals at once is far more often a wiring, jumper or interface problem than a failed board, so the board version on the machine and the version in the cabinet are what we confirm before a replacement is shipped.
Request a quote: send your part number (00-134-932) or the controller serial number, and we confirm the board version, the fit and the lead time before you order.