| Product Condition | New original or used original (Grade A). Please confirm the condition with us before ordering. |
| Shipping Information | Worldwide shipping via DHL, FedEx, and UPS. 3-5 working days to most destinations. Packed with protective film and a reinforced carton. |
| Buyer Benefits |
|
| Item Location | Ships from Shanghai, China. Lead time confirmed with your inquiry. |
| Payment Information | PayPal, T/T, and Alibaba Trade Assurance accepted. Send your inquiry for a quotation. |
12,000+ parts in stock,Tested before shipping,Reply within 24 hours
InquiryThe KUKA 00-127-755 is the CI3 Extended board of the ESC electronic safety circuit in the KR C2 edition 2005 robot controller. KUKA describes the CI3 Extended board as an integral part of the ESC safety logic, a processor-assisted safety system: it connects the individual nodes of the ESC system to the corresponding customer interface, it has its own node, and it is used to indicate the states of the safety circuit, such as the operating mode, the drives on state and the local emergency stop. The board weighs 1.14 kg and carries customs HS code 85389091. It is the board that decides whether the safety chain of the cell is closed, so a fault on it does not stay a display problem: the controller reports a safety fault and the drives will not enable. Send us the article number on the board in your cabinet or the controller serial number, and we confirm the match before you order.
| Manufacturer | KUKA (original spare part) |
| Part Number | 00-127-755 |
| Catalogue name | CI3 Extended, CI board ESC 3.0 Extended |
| Type | CI3 board of the ESC electronic safety circuit |
| Controller series | KUKA KR C2 edition 2005 |
| Function | Connects the individual nodes of the ESC system to the corresponding customer interface |
| Node | Has its own node, and indicates the operating modes, the drives on state and the local emergency stop |
| Net weight | 1.14 kg |
| Customs HS code | 85389091 |
| Condition | New original or used original. Please confirm the condition with us before ordering. |
| Details confirmed before supply | The board variant and the fitted configuration are confirmed against the board in your cabinet before we ship, because the CI3 family exists in several versions with different functions. Send us the article number on the board or the controller serial number. |
Send the article number printed on the board, the controller serial number or a photo of the board, and we confirm the match before you order.
The safety logic of a robot controller is a separate system from the motion control, and it is built so that the two do not depend on each other. The ESC is the electronic safety circuit that closes the chain of protective signals, and the CI3 board is the hardware that carries that chain inside the cabinet. The way it works is what makes the board safety relevant: each ESC chip sends a bit pattern to its outputs and compares the return signals with that pattern, so a wire that breaks, a contact that sticks or a channel that only partly works is detected rather than ignored. The KUKA documentation for the KR C2 edition 2005 names four CI3 variants, and the difference between them is what decides which one a cabinet needs. The CI3 Standard board is the ESC board without a node of its own, and it only connects the nodes that are present. The CI3 Extended board is the ESC board with a node, and it is the one that connects the individual nodes of the ESC system to the corresponding customer interface and indicates the operating modes, the drives on state and the local emergency stop. The CI3 Bus board is for the connection to SafetyBus p, and the CI3 Tech board is for RoboTeam, the shared pendant and SafeRobot. That is why the board in a cabinet has to be identified by its article number and by the node configuration it was fitted with, and why the article number on the old board and the controller it came from are what we confirm before a replacement is shipped.
The KUKA documentation for the KR C2 edition 2005 sets out the ESC diagnosis in the controller, where the state of every node in the safety circuit and the accumulated errors are shown, and where the recorded data is written to a log file. It also describes the indicators on the CI3 board itself: by monitoring the state of the LEDs on the board it is possible to check the 24 V power supply, the 5 V supply of the ESC node, the communication status of each node and the state of the fuses, and on the boards there is a red LED for each fuse which lights up if that fuse is defective. Please contact us with the fault code shown on your controller for an accurate diagnosis of your cabinet. One point is worth keeping in mind when this board is replaced: the fault that appears on several safety signals at once is far more often a wiring, jumper or interface problem than a failed board, so the board version on the machine and the version in the cabinet are what we confirm before a replacement is shipped. The other point is that the safety functions have to be verified again afterwards, because the KUKA maintenance schedule asks for the emergency stop and the mode selector switch to be function tested every six months, and the documentation requires the safety functions to be verified after every recommissioning.
Request a quote: send your part number (00-127-755) or the controller serial number, and we confirm the board variant, the fit and the lead time before you order.
If you have any suggestions, please contact us
Contact Us