ABB 3HAC049089-005 CPCS Floor Cable 15 m for IRC5 IRB 1200
3HAC049089-005 is the ABB CPCS Floor Cable, IRC5, 15m — the 15 metre floor cable that links an IRC5 controller cabinet to an IRB 1200 robot. ABB lists the length in the part name, and the -005 suffix belongs to the 15 m version: the 30 m version is 3HAC049089-007, and the cabinet-internal Harness CP/CS/PBUS 30m is a different part number altogether. Send us the number on your cable label, the cabinet nameplate and the robot model, and we confirm the length and version before you order.
Specifications
| Part Number |
3HAC049089-005 |
| ABB Product Name |
CPCS Floor Cable, IRC5, 15m — the description used in the ABB catalog, invoice and product name fields |
| Cable Type / Route |
Floor cable between the IRC5 controller cabinet and the robot, laid along the floor of the cell |
| Published Length |
15 m (ABB product net length 15,000 mm) |
| Published Weight |
1.88 kg net / 1.88 kg gross |
| Where Used |
ABB IRB 1200, one cable per robot (ABB spare parts catalog). Confirm the robot model from its nameplate. |
| Country of Origin |
China (CN) |
| Customs Tariff Number |
85444290 |
| Length Variants |
3HAC049089-001 (3 m), 3HAC049089-004 (7 m), 3HAC049089-006 (22 m) and 3HAC049089-007 (30 m) are other lengths with their own ABB numbers. Each is a different part from this one. The 30 m cabinet-internal Harness CP/CS/PBUS is a separate cable family. |
| Condition |
New original or used original. Please confirm the condition with us before ordering. |
The suffix decides the length: -005 is 15 m and -007 is 30 m. A 30 m cabinet harness is another family entirely. Send us the number on the cable label, the cabinet nameplate, the robot model and the distance between the cabinet and the robot, and we confirm the version before we quote.
Industrial Applications
- Linking an IRC5 controller cabinet to an IRB 1200 robot in assembly, handling and machine-tending cells.
- Replacing a floor cable that has been crushed, cut or worn by traffic in the cell.
- Cell rebuilds and robot relocations where the cabinet-to-robot distance changes and the cable length must be checked.
- Service stock for maintenance teams running several IRC5 / IRB 1200 cells from one spares inventory.
- Correcting a spares list that records this number as a 30 m cabinet harness when the fitted item is the 15 m floor cable.
Design Purpose
- One floor cable carries the controller-to-robot connections across the cell, so the cabinet can stand clear of the robot working area.
- A 15,000 mm length matched to the standard cabinet-to-robot distance of this IRB 1200 configuration.
- A defined ABB number per length, so the cable is ordered against the installed distance instead of a generic metre value.
- Factory-terminated ends that keep the connector layout of the IRC5 cabinet and the robot base.
- A replaceable external cable, so a damaged floor run does not require work inside the controller cabinet.
Common Failure Modes
- After the floor cable is exchanged, isolate and lock out the cell, route the new cable along the protected floor path and secure it away from forklift and AGV traffic, check both connector ends and their strain reliefs, then power up and update the revolution counters from the FlexPendant (Calibration → Rev Counter Update) with each axis jogged to its calibration mark, and verify axis positions before returning the robot to production. Our ABB revolution counter guide covers the checks.
- Intermittent communication or axis faults after the cable is moved — with the power off, inspect the floor run for crushing, tight bends and connector damage, then send us a photo of the label and both connector ends.
- The jacket looks intact but internal conductors are broken after a forklift or AGV pass — replace the complete floor cable and reroute it through a protected path. Send us the cable label so we confirm the length.
- The 30 m version is ordered for a 15 m run — 3HAC049089-007 is the 30 m cable. Check the suffix on the fitted cable label before the order is placed.
- A cabinet-internal CP/CS/PBUS harness is ordered in place of the floor cable — that is a separate cable family for a different position in the cell. Send us a photo of the installed cable route and we identify it.
- The length is taken from the parts list instead of the installed distance — measure the cabinet-to-robot run and send us the measurement with the cable label.
Why Choose Us
- Supplied against ABB part number 3HAC049089-005, with the 15 m length matched to your cabinet-to-robot distance before packing.
- We check the number on the cable label, the cabinet nameplate and the robot model before we quote, so a 30 m or cabinet-harness cable is not sent.
- New original or used original — the condition is confirmed with you before you order.
- Photos of the actual cable, its label, both connector ends and the jacket provided on request.
- Packed for export from Shanghai with the connectors capped and the coil secured, and shipped worldwide.
Related Products
Request a quote for current pricing and lead time – send us the number on your cable label, the cabinet nameplate, the robot model and the cabinet-to-robot distance, and we confirm the length and version before you order.