| Product Condition | New original or used original. Please confirm the condition with us before ordering. |
| Shipping Information | Ships from Shanghai, China. Delivery lead time: 3-5 working days after order confirmation. Worldwide delivery by DHL / FedEx / UPS, with the resistor assembly braced and the connector capped for transport. |
| Buyer Benefits |
|
| Item Location | Ships from Shanghai, China. |
| Payment Information | PayPal / T/T / Alibaba Trade Assurance. |
12,000+ parts in stock,Tested before shipping,Reply within 24 hours
Inquiry3HAC032586-001 is the ABB Bleeder Unit for the high voltage drive section of the IRC5 controller cabinet. ABB's product data sheet lists it for use in HV, Drive System 09 and supplies it as a complete assembly with the harness and the 2-pole connector 3HAC035373-001. It discharges the energy left in the drive DC link when the robot stops or the cabinet is switched off, so the bus does not stay live for the next person who opens the cabinet. ABB's IRC5 spare parts list also carries separate low voltage and higher power bleeder assemblies, so send us the number from your bleeder label, the controller nameplate and the drive system designation, and we confirm the 2 kW HV variant before you order.
| Manufacturer | ABB (original spare part) |
| Part Number | 3HAC032586-001 |
| ABB Catalog Description | Bleeder Unit (ABB product data sheet); listed in the IRC5 Product manual spare parts list as Bleeder Unit, 2 kW |
| Drive System Fit | For use in HV, Drive System 09 (ABB product data sheet). Send us the controller nameplate and we confirm the drive system in your cabinet before you order. |
| Used In | IRC5 Single controller, IRC5 M2004 drive module (ABB product data sheet Where Used and product specific part data) |
| Supplied As | One complete bleeder assembly with the harness and the 2-pole connector 3HAC035373-001, not a loose resistor element |
| Different Parts | 3HAC035583-001 (LV, Drive System 09) and 3HAC050878-001 (4 kW assembly) are different parts listed in the same ABB spare parts table |
| Function | Dissipates the energy held in the drive DC link so the cabinet discharges after a power off or an emergency stop |
| Fit Confirmation | Send us the number from your bleeder label, the controller nameplate, the drive system designation and a photo of the fitted unit. We confirm the variant before you order. |
| Condition | New original or used original. Please confirm the condition with us before ordering. |
Send us the number from your bleeder label, the controller nameplate and the drive system designation, and we confirm the match before you order.
The drive section of an IRC5 cabinet works on a high voltage DC link, and that link holds a charge after the cabinet is switched off. The bleeder unit takes that charge away. Without it the bus voltage stays high, and the next person who opens the cabinet is working on a live bus. It also protects the drive electronics: a bus that is not discharged when it should be can overshoot when the robot decelerates hard or stops on an emergency. ABB supplies this as a complete assembly with the harness and the keyed 2-pole connector, so the unit is exchanged as a whole rather than repaired in place. Because the harness sits next to a hot resistor, a burnt harness means the whole assembly is replaced, not only the resistor element. Send us the number from your bleeder label and the controller nameplate, and we confirm the correct variant before you order.
Check the DC link overvoltage entries in our ABB IRC5 alarm codes guide, then send us the fault code shown on the pendant, the controller nameplate and a photo of the fitted unit, and we confirm the bleeder variant before you order. Isolate and lock out all supplies and have the DC link discharge verified by a qualified technician before the unit is touched. After refitting, power up with no load, confirm the bus discharges on a controlled stop, and run one full cycle before returning to automatic production.
Request a quote for current pricing and lead time – send us the number from your bleeder label, the controller nameplate and the drive system designation, and we confirm the 2 kW HV variant before you order.
If you have any suggestions, please contact us
Contact Us